How To Operate The Cold Pressed Terminal Blocks

Publish Time: Author: Site Editor Visit: 22

Distribution box When using it, you need to fully understand the cold-pressed terminal to be operated and be familiar with its operation method to a certain extent, so as to effectively ensure its correct operation. For cold-pressed terminals that do not have anti-misoperation functions, color codes or marks should be used to identify them, or whether the appropriate models correspond before connection, and ensure correct positioning when connected to each other; special attention should be paid to prevent mis-insertion of pin sockets, otherwise the cold-pressed terminals will be damaged and cause accidental electrical contact; the cold-pressed terminals should be connected in place. In special occasions that are not easy to check, detailed regulations should be made in the corresponding operating procedures, and they can be checked through a peephole.

When the cold-pressed terminal is terminated, it should be terminated and inspected strictly in accordance with the corresponding termination specifications and requirements during operation. During operation, it should be terminated according to the corresponding contact number. The maximum insulation layer thickness between the selected cable conductors should match the contact spacing, and the cable core should match the contact terminal. When the contacts are crossed and paralleled, they should be handled.

When welding the cold-pressed terminal, the corresponding power of the soldering iron should be selected according to the bare wire diameter. The welding time of each contact piece is generally not more than 5S. Care should be taken not to let the flux penetrate into the insulator to avoid reducing the insulation resistance of the product.

When the cold-pressed terminal is in its separated state, protective caps should be installed or other dust-proof measures should be taken; if the cold-pressed terminal is not separated for a long time after connection, a fuse can be installed between the plug and the socket. When cleaning the cold-pressed terminal, a silk cloth dipped in anhydrous ethanol can be used and used after drying. Chemical solvents such as acetone that may have a harmful effect on the connector are not allowed.

When the cold-pressed terminal is connected or separated, the axis of the plug and the socket should be overlapped as much as possible, and the cable should be straightened to avoid the plug from being subjected to tangential force and prevent the cable from sagging and causing damage to the connector. Before the cold-pressed terminal is not properly connected or completely locked.

How To Operate The Cold Pressed Terminal Blocks